FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package package.teste#1.0.7-draft (94 ms)

Package package.teste
Type StructureDefinition
Id Id
FHIR Version R4B
Source https://simplifier.net/resolve?scope=package.teste@1.0.7-draft&canonical=https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DevicePTCore
Url https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DevicePTCore
Version 1.0.0
Status draft
Date 2024-05-15T12:02:59.9500946+00:00
Name DevicePTCore
Title Device PT Core
Experimental False
Type Device
Kind resource

Resources that use this resource

StructureDefinition
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/BundlePTCore Bundle PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CompositionPTCore Composition PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/ListPTCore List PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/MessageHeaderPTCore MessageHeader PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/SchedulePTCore Schedule PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/AdverseEventPTCore AdverseEventPTCore
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CarePlanPTCore Care Plan PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DevicePTCore Device PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DeviceUseStatementPTCore Device Use Statement PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DocumentReferencePTCore Document Reference PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/ImagingStudyPTCore Imaging Study PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/MediaPTCore Media PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/MedicationAdministrationPTCore Medication Administration PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/MedicationRequestPTCore Medication Request PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/ObservationPTCore Observation PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/ProcedurePTCore Procedure PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/QuestionnaireResponsePTCore Questionnaire Response PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/ServiceRequestPTCore Service Request PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DocumentReferencePTPS Document Reference PT PS

Resources that this resource uses

StructureDefinition
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore CodeableConcept PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/MetaPTCore Meta PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/IdentifierPTCore Identifier PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/LocationPTCore Location PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/OrganizationPTCore Organization PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/PatientPTCore Patient PT Core
https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DevicePTCore Device PT Core


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "DevicePTCore",
  "url" : "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DevicePTCore",
  "version" : "1.0.0",
  "name" : "DevicePTCore",
  "title" : "Device PT Core",
  "status" : "draft",
  "date" : "2024-05-15T12:02:59.9500946+00:00",
  "publisher" : "SPMS",
  "contact" : [
    {
      "name" : "Interoperabilidade Semântica",
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.spms.min-saude.pt"
        }
      ]
    }
  ],
  "fhirVersion" : "4.3.0",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Device",
  "baseDefinition" : "http://hl7.org/fhir/StructureDefinition/Device",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Device.meta",
        "path" : "Device.meta",
        "definition" : "Os metadados sobre o recurso. Este é o conteúdo mantido pela infraestrutura. As alterações no conteúdo nem sempre podem estar associadas às alterações de versão do recurso.",
        "type" : [
          {
            "code" : "Meta",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/MetaPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.identifier",
        "path" : "Device.identifier",
        "definition" : "Identificadores de instância exclusivos atribuídos a um dispositivo por fabricantes, outras organizações ou proprietários.",
        "type" : [
          {
            "code" : "Identifier",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/IdentifierPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.identifier.type.coding.id",
        "path" : "Device.identifier.type.coding.id",
        "comment" : "."
      },
      {
        "id" : "Device.definition",
        "path" : "Device.definition",
        "definition" : "A referência à definição do dispositivo.",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DeviceDefinitionPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.udiCarrier",
        "path" : "Device.udiCarrier",
        "definition" : "Unique device identifier (UDI) atribuído à etiqueta ou embalagem do dispositivo. Observe que o Dispositivo pode incluir vários udiCarriers, pois pode incluir apenas o udiCarrier para a jurisdição em que é vendido ou para múltiplas jurisdições em que poderia ter sido vendido."
      },
      {
        "id" : "Device.udiCarrier.deviceIdentifier",
        "path" : "Device.udiCarrier.deviceIdentifier",
        "definition" : "Parte fixa obrigatória do UDI"
      },
      {
        "id" : "Device.udiCarrier.issuer",
        "path" : "Device.udiCarrier.issuer",
        "definition" : "Organização emissora de UDI"
      },
      {
        "id" : "Device.udiCarrier.jurisdiction",
        "path" : "Device.udiCarrier.jurisdiction",
        "definition" : "Autoridade UDI regional"
      },
      {
        "id" : "Device.udiCarrier.carrierAIDC",
        "path" : "Device.udiCarrier.carrierAIDC",
        "definition" : "String de código de barras legível por máquina UDI"
      },
      {
        "id" : "Device.udiCarrier.carrierHRF",
        "path" : "Device.udiCarrier.carrierHRF",
        "definition" : "Sequência de código de barras legível por humanos UDI"
      },
      {
        "id" : "Device.udiCarrier.entryType",
        "path" : "Device.udiCarrier.entryType",
        "definition" : "Uma entrada codificada para indicar como os dados foram inseridos."
      },
      {
        "id" : "Device.status",
        "path" : "Device.status",
        "definition" : "Status da disponibilidade do dispositivo."
      },
      {
        "id" : "Device.statusReason",
        "path" : "Device.statusReason",
        "definition" : "Motivo do estado de disponibilidade do Dispositivo.",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.distinctIdentifier",
        "path" : "Device.distinctIdentifier",
        "definition" : "A cadeia de identificação distinta"
      },
      {
        "id" : "Device.manufacturer",
        "path" : "Device.manufacturer",
        "definition" : "Nome do fabricante do dispositivo"
      },
      {
        "id" : "Device.manufactureDate",
        "path" : "Device.manufactureDate",
        "definition" : "Data em que o dispositivo foi fabricado"
      },
      {
        "id" : "Device.expirationDate",
        "path" : "Device.expirationDate",
        "definition" : "Data e hora de validade deste dispositivo (se aplicável)"
      },
      {
        "id" : "Device.lotNumber",
        "path" : "Device.lotNumber",
        "definition" : "Número do lote de produção"
      },
      {
        "id" : "Device.serialNumber",
        "path" : "Device.serialNumber",
        "definition" : "Número de série atribuído pelo fabricante"
      },
      {
        "id" : "Device.deviceName",
        "path" : "Device.deviceName",
        "definition" : "O nome do dispositivo fornecido pelo fabricante"
      },
      {
        "id" : "Device.deviceName.name",
        "path" : "Device.deviceName.name",
        "definition" : "O nome que identifica o dispositivo"
      },
      {
        "id" : "Device.deviceName.type",
        "path" : "Device.deviceName.type",
        "definition" : "O tipo de deviceName.\nUDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName."
      },
      {
        "id" : "Device.modelNumber",
        "path" : "Device.modelNumber",
        "definition" : "O número do modelo do fabricante do dispositivo"
      },
      {
        "id" : "Device.partNumber",
        "path" : "Device.partNumber",
        "definition" : "O número da peça ou número de catálogo do dispositivo"
      },
      {
        "id" : "Device.type",
        "path" : "Device.type",
        "definition" : "O Tipo de dispositivo.",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.specialization",
        "path" : "Device.specialization",
        "definition" : "Os recursos suportados nm dispositivo, os standards aos quais o dispositivo está em conformidade para uma finalidade específica e usados ​​para a comunicação"
      },
      {
        "id" : "Device.specialization.systemType",
        "path" : "Device.specialization.systemType",
        "definition" : "O standard usado para operar e comunicar",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.specialization.version",
        "path" : "Device.specialization.version",
        "definition" : "A versão do standard usada para operar e comunicar"
      },
      {
        "id" : "Device.version",
        "path" : "Device.version",
        "definition" : "O design atual do dispositivo ou a versão do software em execução no dispositivo"
      },
      {
        "id" : "Device.version.type",
        "path" : "Device.version.type",
        "definition" : "O tipo da versão do dispositivo, por ex. fabricante, aprovado, interno",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.version.component",
        "path" : "Device.version.component",
        "definition" : "Um único componente da versão do dispositivo"
      },
      {
        "id" : "Device.version.value",
        "path" : "Device.version.value",
        "definition" : "O texto da versão."
      },
      {
        "id" : "Device.property",
        "path" : "Device.property",
        "definition" : "As definições de configuração reais de um dispositivo conforme ele realmente opera, por exemplo, status de regulação, propriedades de tempo"
      },
      {
        "id" : "Device.property.type",
        "path" : "Device.property.type",
        "definition" : "Código que especifica a propriedade DeviceDefinitionPropetyCode (Extensible)",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.property.valueQuantity",
        "path" : "Device.property.valueQuantity",
        "definition" : "Valor da propriedade como quantidade"
      },
      {
        "id" : "Device.property.valueCode",
        "path" : "Device.property.valueCode",
        "definition" : "Valor da propriedade como um código, por exemplo, NTP4 (sincronizado com NTP)",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.patient",
        "path" : "Device.patient",
        "definition" : "Paciente ao qual o dispositivo está fixado",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/PatientPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.owner",
        "path" : "Device.owner",
        "definition" : "A Organização responsável pelo dispositivo.",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Organization",
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/OrganizationPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.contact",
        "path" : "Device.contact",
        "definition" : "Detalhes do humano/organização para suporte"
      },
      {
        "id" : "Device.location",
        "path" : "Device.location",
        "definition" : "Onde o dispositivo é encontrado",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Location",
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/LocationPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.url",
        "path" : "Device.url",
        "definition" : "Endereço de rede para contactar o dispositivo"
      },
      {
        "id" : "Device.note",
        "path" : "Device.note",
        "definition" : "Notas e comentários do dispositivo"
      },
      {
        "id" : "Device.safety",
        "path" : "Device.safety",
        "definition" : "Características de segurança do dispositivo",
        "type" : [
          {
            "code" : "CodeableConcept",
            "profile" : [
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/CodeableConceptPTCore"
            ]
          }
        ]
      },
      {
        "id" : "Device.parent",
        "path" : "Device.parent",
        "definition" : "O dispositivo ao qual este dispositivo está conectado ou faz parte",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Device",
              "https://spms.min-saude.pt/fhir-r4B/iop/StructureDefinition/DevicePTCore"
            ]
          }
        ]
      }
    ]
  },
  "text" : {
  }
}

XIG built as of ??metadata-date??. Found ??metadata-resources?? resources in ??metadata-packages?? packages.